Downloading: s3://natera-rnd-pltf-dev-nextflow-scratch-01/work/38/4328b383c01c3cee1513d81df0b07d/.command.sh
Downloading: s3://natera-platform-sandbox/pipeline-inputs/illumina_run_folders/data/20260107_LH00166_0227_A23KKJ7LT4/RunParameters.xml
Downloading: s3://natera-platform-sandbox/pipeline-inputs/illumina_run_folders/data/20260107_LH00166_0227_A23KKJ7LT4/bclconvert_samplesheet.csv
Downloading: s3://natera-platform-sandbox/pipeline-inputs/illumina_run_folders/data/20260107_LH00166_0227_A23KKJ7LT4/Data/Intensities/s.locs
Downloading: s3://natera-platform-sandbox/pipeline-inputs/illumina_run_folders/data/20260107_LH00166_0227_A23KKJ7LT4/Data/Intensities/BaseCalls/L007
Downloading: s3://natera-rnd-pltf-dev-nextflow-scratch-01/work/38/4328b383c01c3cee1513d81df0b07d/.command.run
Downloading: s3://natera-platform-sandbox/pipeline-inputs/illumina_run_folders/data/20260107_LH00166_0227_A23KKJ7LT4/RunInfo.xml
==> STAGING COMPLETE (7 inputs)
WARNING: skipping lane 1 because RunInfo.xml file lists no tiles for it
WARNING: skipping lane 2 because RunInfo.xml file lists no tiles for it
WARNING: skipping lane 3 because RunInfo.xml file lists no tiles for it
WARNING: skipping lane 4 because RunInfo.xml file lists no tiles for it
WARNING: skipping lane 5 because RunInfo.xml file lists no tiles for it
WARNING: skipping lane 6 because RunInfo.xml file lists no tiles for it
WARNING: skipping lane 8 because RunInfo.xml file lists no tiles for it
Sample sheet being processed by common lib? Yes
SampleSheet Settings:
FastqCompressionFormat = gzip
NoLaneSplitting = FALSE
OverrideCycles = Y151;I10;I10;Y151
SoftwareVersion = 4.3.6
Index Read 2 (i5): The barcode and UMI outputs will be processed and output in Reverse Complement of Sample Sheet inputs. OverrideCycles bases for this read will be interpreted in reverse.
shared-thread-linux-native-asio output is disabled
bcl-convert Version 4.4.6
Copyright (c) 2014-2025 Illumina, Inc.
Command Line: --tiles s_7 --output-directory output --bcl-input-directory rundir --sample-sheet rundir/SampleSheet.csv
Conversion Begins.
Input BCL Information:
Read Structure: Y151;I10;I10;Y151
RunInfo.xml file lists: 8 lanes, 6272 tiles
BCL file format: cbcl
Positions file format: slocs
Filter file format: filter
Conversion Information:
Tile filtering: converting 784/6272 tiles
Sample Count for Lane 1: 48
Lane 1 will be skipped because there are no tiles to convert (not listed in RunInfo.xml tile list?)
Sample Count for Lane 2: 48
Lane 2 will be skipped because there are no tiles to convert (not listed in RunInfo.xml tile list?)
Sample Count for Lane 3: 48
Lane 3 will be skipped because there are no tiles to convert (not listed in RunInfo.xml tile list?)
Sample Count for Lane 4: 48
Lane 4 will be skipped because there are no tiles to convert (not listed in RunInfo.xml tile list?)
Sample Count for Lane 5: 48
Lane 5 will be skipped because there are no tiles to convert (not listed in RunInfo.xml tile list?)
Sample Count for Lane 6: 48
Lane 6 will be skipped because there are no tiles to convert (not listed in RunInfo.xml tile list?)
Sample Count for Lane 7: 48
Sample Count for Lane 8: 48
Lane 8 will be skipped because there are no tiles to convert (not listed in RunInfo.xml tile list?)
Expected number of sample FASTQ files to be created: 96
# CPU hw threads available: 64
Parallel Tiles: 4. Threads Per Tile: 16
SW compressors: 64
SW decompressors: 32
SW FASTQ compression level: 1
Lane 7 Post-run Information:
Total clusters: 4276187445
Total Genomic Reads: 8552374890
Total Genomic Input Gigabases 1291.41
Minimum reads for a sample: 2568238
Maximum reads for a sample: 296396798
Average reads per sample: 168687909.92
Undetermined reads: 455355214
Conversion Complete.